Air Cooler Heat Exchanger Design
Aches for process plants are normally just called aircoolers but should not be confused with devices for cooling air best described as air chillers.
Air cooler heat exchanger design. Of 180f to less than 10 f above ambient of 105f 650 to 1 000 psig operating pressure. Tube configuration used in this guideline. A fan or blower which moves the air. One or more bundles of the heat transfer surface.
The software will design horizontal induced draft or forced draft units for liquid and gas services and will produce a three page summary of all results and a basic drawing representation. The obvious advantage of an ache is that it does not require water which means that plants requiring large. 2nd bundle 1 200 bpsd of condensate sp. Air cooled heat exchanger.
Where expensive or insufficient water supplies are encountered or where cooling water pumping or treating costs are excessive it is often found that air cooled units are desirable for several services. The fluids may be separated by a solid wall to prevent mixing or they may be in direct contact. An air cooled exchanger is used to cool fluids with ambient air. Gr 0 63 with less than 2 co2 at an inlet temp.
Air heat exchanger manufacturer stefani combines typical italian creativity with a strong spirit of innovation which leads the company to propose ever more performing air cooler units blast chillers condensers and dry coolers for industrial and commercial refrigeration. 15 mm scfd of wet natural gas sp. Here in the latter case the heat capacities c p 0 for gases are required to determine the heat necessary to bring the chemical compound increase to the reaction temperature. Process design of air cooled heat exchangers air coolers project standards and specifications page 4 of 19 rev.
An air cooled heat exchanger consists of the following primary components refer to fig. Components of an air cooled heat exchanger. 1 inch od tube is the most popular diameter and the most common fins are 1 2 inch or 5 8 inch high. The heat capacity of gases is essential for some process engineering design e g for air cooled heat exchanger and for gas phase chemical reactions.
A mechanical driver and power transmission for running the fan or blower. They are widely used in space heating refrigeration air conditioning power stations chemical plants petrochemical plants petroleum refineries natural. A heat exchanger is a system used to transfer heat between two or more fluids heat exchangers are used in both cooling and heating processes. 1 inch od tube 5 8 inch fin height 10 fins per inch and 2 5 inch triangular pitch.
The design of an ache is more complex than for a shell and tube heat exchanger as there are many more components and variables.