Air Admittance Valve In Attic
Used most commonly at an island sink or vanity the vents are also located in the attic to prevent the roof penetrations as seen above on the front roof line elevation.
Air admittance valve in attic. Both the ipc and irc plumbing provisions allow air admittance valves on all vents except for pneumatic sewage ejectors except on the required one 3 vent that. In this video i talk about a cheater vent that is sometimes used in plumbing systems. Minnesota is a prime example of this. They re designed to address negative air pressure in the drain system created when a fixture is drained.
In these rare cases plumbers use an air admittance valve. Situations in which an aav makes a plumber s life easier include installation of a kitchen island sink or a bathroom lavatory in a basement on the side of. This advanced air admittance valve aav protects the trap seals in the drainage system by allowing the intake of air so a soil pipe can maintain the right level of pressure within the drainage system. A cheater vent is often referred to as an air admittance valve and is.
Similar in function to air admittance valves these vents allow air to be drawn in when the waste plumbing is under negative pressure. Complies to asse standard 1050 and 1051 and iapmo listed sizes. The maxi vent is discreet it can be installed in the attic area or even below the flood level of the highest connected branch. It is not unusual that you should be seeing air admittance valves on plumbing vents in oklahoma since oklahoma has adopted the international plumbing code and the plumbing provisions of the international residential code statewide.
Superior engineering along with stringent quality standards ensure unmatched performance. The wastewater being sent down the drain referred to as a slug pushes air in the pipe in front of it leaving behind an area of. Oatey offers a wide range of sure vent air admittance valves to enable installation in virtually any application. An air admittance valve or aav provides a viable way to vent a sink drain p trap in the event that hooking up the drain to the building s vent network is prohibitively costly or impossible.
This one way valve is designed to allow air into the plumbing when negative pressure is developed from draining. In the event that your walls do not leave enough space for any of the above vents then the local code may allow you to opt for an air admittance valve aav. Air admittance valves aav are one way vents installed after the trap on the drain line of a fixture. Oatey sure vent aavs are available in four sizes ranging from 8 stack 24 branch dfu to 160 stack 500 branch dfu.
Automatic air vents are no longer approved and should be replaced. Air admittance valves aka studor vents are negative pressure activated one way mechanical valves. Although these are very useful devices in some states they re not allowed.